International Journal of Concrete Technology
Advantages of Use of Base Isolator and Fluid Viscous Dampers
Abstract
Several disastrous earthquakes have struck the world in recent decades, resulting in increasing humandeaths due to building collapse and significant structural damage The damages due to seismic actionshave made us realise that structures (residential, industrial, bridges etc) must be designed andconstructed to be resistant to earthquake. The building which are not designed properly will be proneto major damage. The prime option to withstand these building during severe earthquakes is seismicimprovement. There are multiple options available for seismic improvement of the building. The baseisolation technique and energy dissipation approach, on the other hand, are the most popular seismicprotection techniques. Seismic base isolation technology with use of various isolators energy disipiationtechniques (fuid viscous damper) are being used to minimize the seismic response of structure ascompared to structure with rigid base. Similarly, energy dissipation techniques like Dampers are widelyused. The techniques of base isolator and fluid viscous damper help to lessen the seismic response of astructure when compared to a fixed base construction.Keywords: Base isolator, viscous dampers, disastrous earthquakes, building collapse, seismic actionsReferences (37)
- R. V. Vajreshwari Umachagi, Katta Venkataramana, G. R. Reddy, “Applications of Dampers for
- Vibration Control of Structures: an Overview,” Int. J. Res. Eng. Technol., vol. 02, no. 13, pp. 6–11,
- , doi:10.15623/ijret.2013.0213002.
- A. M. G. Arya, Alice T.V, “Seismic Analysis of High Damping Rubber Bearings for Base
- Isolation,” Int. J. Res. Eng. Technol., vol. 04, no. 01, pp. 321–327, 2015, doi:
- 15623/ijret.2015.0401048.
- S. D. Raghunandan M H, “Seismic Pounding Between Adjacent Rc Buildings With and Without
- Base Isolation System,” Int. J. Res. Eng. Technol., vol. 04, no. 06, pp. 367–375, 2015, doi:
- 15623/ijret.2015.0406062.
- G. S. H. Vinodkumar Parma, “Advances in Control, Chemical Engineering, Civil Engineering and
- Mechanical Engineering - European Conference of Chemical Engineering, ECCE’10, European
- Conference of Civil Engineering, ECCIE’10, European Conference of Mechanical Engineering,
- ECME’10, Eur,” Eur. Conf. Chem. Eng. ECCE’10, Eur. Conf. Civ. Eng. ECCIE’10, Eur. Conf.
- Mech. Eng. ECME’10, Eur. Conf. Control. ECC’10, pp. 2319–2322, 2010.
- A. K. Sonali Anilduke, “Comparision of Building for Sesmic Response By Using Base Isolation,”
- Int. J. Res. Eng. Technol., vol. 04, no. 06, pp. 237–241, 2015, doi:10.15623/ijret.2015.0406039.
- S. N. Swathirani.K.S, Muralidhara.G.B, “Eatrhquake Response of Reinforced Cocrete Multi Storey
- Building With Base Isolation,” Int. J. Res. Eng. Technol., vol. 04, no. 10, pp. 158–167, 2015, doi:
- 15623/ijret.2015.0410028.
- M. W. A. H. Okine Michael Nii Sarbah, Zhao Jianchang, “Seismic Base Isolation in Strengthening
- an Existing Retrofitted Masonry-Reinforced Concrete Building in Huating - China,” Int. J. Res.
- Eng. Technol., vol. 04, no. 10, pp. 168–175, 2015, doi:10.15623/ijret.2015.0410029.
- S. H. Ju, C. C. Yuantien, and W. K. Hsieh, “Study of lead rubber bearings for vibration reduction
- in high-tech factories,” Appl. Sci., vol. 10, no. 4, 2020, doi:10.3390/app10041502.
- H. N. Shankarling S Mandewali, “Performance Evaluation of Lead Rubber Isolators Under Seismic
- Loads,” Int. J. Res. Eng. Technol., vol. 05, no. 26, pp. 21–24, 2016, doi:
- 15623/ijret.2016.0526005.
- M. A. Baig, M. I. Khan, and M. Amir Baig, “Seismic Analysis of Fixed Base and Base Isolated
- Building Using Lead Rubber Bearing Pushover Analysis of Steel Frame View projectBenchmarking of Indian Seismic CODE IS1893:2016 View project Seismic Analysis of Fixed Base
- and Base Isolated Building Using ,” vol. 5, no. August, 2018, [Online]. Available:
- https://www.researchgate.net/publication/327271116
- W. A. Al-Kutti and A. B. M. S. Islam, “Potential design of seismic vulnerable buildings
- incorporating lead rubber bearing,” Buildings, vol. 9, no. 2, 2019, doi:10.3390/buildings9020037.
- P. S. Gitanjali Sahu, “Comparative Analysis of Effects of Base Isolator & Fluid Viscous Damper
- on Response of A RCC Structure Gitanjali,” Int. J. Res. Eng. Technol., vol. 06, no. 11/Nov201,
- S. K. Sahu, “Seismic Response of Asymmetric Reinforced Concrete Structure with Lead Rubber
- Bearing,” vol. 7, no. 6, pp. 30–36, 2020.