International Journal of Environmental Chemistry
A New Multidentate Fluorescent Chemosensor for metal ions: Synthesis and Fluorescence Response
Abstract
We report the synthesis and the fluorescence response to metal ions of a multidentate pyridyl-based ligand in MeCN/H2O (3/7) solution. The ligand was synthesided via overnight refluxing of a ethanolic mixture of 2,6-diamino pyridine and di(pyridine-2-yl)methanone. studies reveal the ligand display sensing response ability in the presence of certain metal ions. It display significant fluorescent quenching in the presence of Ni2+, Co2+, Zn2+ and Cd2+, with remarkable fluorescence “turn-off” response to Ni2+, which can be used as a design for selective detection of Ni2+ among the studied metal ions. We would like to present preliminary result findings on the synthesis of a novel pyridyl-derived “turn-off” fluorometric probe for Nickel (II) ion. Keywords: chemosensor, metal ions, fluorescent, environment, wastewater treatmentReferences (15)
- A. Warshawsky. In: Rodrigues, A. (Ed.), Ion Exchange: Science and Technology. Martnus Nijhoff Publishers. Dordrecht, 1986, p. 69.
- T. M. Suzuki, T. Yokoyama, Polyhedron 1983, 2, pp 127-128.
- EPA, US Federal Register 1979, 44, 69464-69575.
- N. C. Lim, S. V. Pavlova, C. Bruckner, Inorganic Chemistry 48, 2008, 1173.
- H. J. Kim, J. Hong, A. Hong, S. Ham, J. H. Lee, J. S. Kim., Organic Letters 10, 2008, 1963.
- E. M. Nolan, S. J. Lippard. Journal of the American Chemical Society 129, 2007, 5910.
- N. C. Lim, S. Atilgan, T. Ozdemir, E. U. Akkaya, Organic Letters 10, 2008, 4065.
- T. Schwarse; H. Muller; C. Dosche; T. Klamroth; W. Mickler; A. Kelling, et al., Angewandte Chemie International Edition 2007, 46, 1671
- (a) A. Ojida, I. Tkashima, T. Kohira, H. Nonaka, I. Hamachi, J. Am. Chem. Soc. 130, 2008, p. 12095. (b) P.D. Zalewski, I.J. Forbes, W.H. Betts, Biochem. J. 296, 1993, p. 403-408. (c) M.P. Cuajungco, G.J. Lees, Neurobiol. Dis. 4, 1997, 137. (d) A.I. Bush, R.E. Tanzi, Proc. Natl. Acad. Sci. U.S.A. 99, 2002, 7317. (e) S. Maruyama, K. Kikuchi, T. Hirano, Y. Urano, T. Nagano. J. Am. Chem. Soc. 124, 2002, 65 10650. (f) M.D. Shults, D.A. Pearce, B. Imperiali, J. Am. Chem. Soc. 125, 2003, 10591. (g) M. Taki, J.L.Wolford, T.V. O’Halloran, J. Am. Chem. Soc. 126, 2004, 712.
- J. B Neilands, Ann. Rev. Biochem. 1981, 50, p. 715-731. H. Ouchetto, M. Dias, R. Mornet, E. Lesuisse, J. M. Camaro, Bioorg. Med. Chem. 2005, 13, p. 1799.
- Y. Liu, Q. Miao, S-W. Zhan, X-B. Huang, L-F. Zheng, Y-X. Cheng, Macromol. Chem. Phys. 2008, 209, p. 685-694.
- Q. Miao, X-B. Huang, Y-Q. Cheng, Y. Liu, L-L. Zeng, Y-X. Cheng, J. Appl. Polym. Sci. 2009, 111, p. 3137-3143.
- For PET sensors, see: (a) H. M. Kim; M. S. Seo; M. J. An; J. H. Hong; Y. S. Tian; J. H. Choi; O. Kwon; K. J. Lee; B. R. Cho. Angew. Chem., Int. Ed. 2008, 47, 5167. (b) For ICT sensors, see: K. Komatsu; Y. Urano; H. Kojima; T. Nagano. J. Am. Chem. Soc. 2007, 129, 13447.
- (a) Z. Xu; X. Qian; J. Cui; R. Zhang. Tetrahedron 2006, 62, 10117. (b) Y. Zhang; X. Guo; W. Si; L. Jia; X. Qian. Org. Lett. 2008, 10, 473. (c) Z. Xu; X. Qian; J. Cui. Org. Lett. 2005, 7, 3029.
- S. Sobek; B. Boduszek; H. Kozlowski. Inorganica Chimica 85 Acta 355, 2003, 462-465.